These CE / RoHS / FCC recognized 12V Constant Voltage TWP Series LED Waterproof Power Supplies have an IP67 rating for wet or dry locations and can supply up to 50 amps of 12-volt dc power or 600 watts. A universal ac input of 100-240VAC makes this TWP Series LED Waterproof valuable transformer in home and industrial applications. Input and output connections are made using 18AWG bare wire leads.
These IP67 ultrathin TWP Series LED Waterproof Drivers have built-in short circuit, overload, and over-voltage protection and adhere to CE safety standards. Use these small 12V TWP Series LED Waterproof transformers for indoor or outdoor 12VDC LED Lighting Projects.
12V TWP Series IP67 Waterproof Power Supply Features:
1) High-quality anodized aluminum construction
2) High-density double-sided fiberglass PCB with SMT process
3) Thickness within 4cm
4) Smaller size with a bigger power ( 500W )
5) IP67 waterproof performance
6) Superior heat dissipation with a fanless silent design
7) Short circuit, overload, overvoltage, overcurrent, and leakage protection
8) CE & RoHS & FCC & ISO9001 listed
12V TWP Series IP67 Waterproof Power Supply Specifications:
DC Output | DC Voltage: 12V |
Ripple & Noise: 80MV | |
Voltage Tolerance: ±2.0% | |
Line Regulation: ±0.5% | |
Load Regulation: ±1% | |
Setup, Rise Time, Hold Up Time:200ms, 50ms, 20ms/230VAC | |
AC Input | AC Voltage Range: 85-264VAC |
Frequency Range: 47-63Hz | |
Efficiency:90% | |
AC Inrush Current: 20A/115V 40A/230V | |
Leakage Current< 0.5mA /240VAC | |
Protection | Over-load: 105%-150% hiccup mode, Auto-recovery |
Over-voltage: 115%-135% Cut Off the Output, Auto-recovery | |
Over-temp. : Shut down O/P voltage, Auto-recovery | |
Environment | Working temp.: -10~ +60°C (Refer to output load derating curve) |
Working Humidity:20 ~ 90% RH, non-condensing | |
Storage Temp.: -10~ +60°C | |
Storage Humidity: 10 ~ 95% RH | |
Safety | Isolation Resistance:I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC / 25C°/ 70% RH |
Withstand Voltage: I/P-O/P:3KVAC; I/P-FG:1.5KVAC; O/P-FG:0.5KVAC | |
Safety standards: CE, RoHS, FCC, ISO9001 |